People that use our products.

325+ Electricians, Engineers and Energy professionals
trust and use our products.

  • Free shipping on orders over R 2000 in South Africa
  • Satisfied or your money back: 30-day test
  • Two-year warranty
  • Stock kept in South Africa

We love our products and are confident you will love them too! In case things don’t go as planned, our return policy is designed to be as easy as possible for you: We offer a risk-free 30-day money-back guarantee on all purchases.

Meatrol ME537 – Three-phase energy logger

R 8 500.00 Incl. VAT

or 4 interest-free payments of R 2 125.00 with Payflex


The Meatrol ME537 is full colour screen, three phase power quality analyser, externally connected with open type Rogowski coil or voltage type CTs.

Install this meter and log a building’s energy usage.

This three-phase energy logger is ideal for the following:

  • Determining the energy usage/load profile of a building’s energy usage over a period of time.
  • Determining a building’s peak power usage.
  • Testing the quality of supply for example voltage dips and harmonic analysis.

The results from the energy logging can be used to:

  • Identify cost-saving opportunities from energy efficiency measures.
  • Identify cost-saving opportunities from improving a building’s Power Factor and Peak-demand(KVA) requirements.
  • Monitor and check for phase imbalances to prevent overloading one phase.
Weight 0.45 kg
Dimensions 9.6 × 9.6 × 9.4 cm

Sold Out – Get notified when it is back in Stock.

Would you like to be notified when this item is back in stock? Then please complete the form below:

This field is for validation purposes and should be left unchanged.

In stock

GUARANTEED SAFE CHECKOUT
  • Visa Card
  • MasterCard
  • payflex
  • netcash

Payflex – buy now, pay later, 0% interest

This three-phase energy logger is ideal for the following.

  • Determining the energy usage/load profile of a building’s energy usage over a period of time.
  • Determining a building’s peak power usage.
  • Testing the quality of supply for example voltage dips and harmonic analysis, and establishing if voltage levels are in the acceptable range for PV Inverters.
Power consumption graph

The results from the energy logging can be used for the following.

Plan capacity and expansion

  • Add machines or a new production line — confirm your supply has the headroom before you order equipment.
  • Install EV charge points — work out how many your existing connection can support.
  • Add heat pumps, HVAC, or other large loads — check available capacity before installation.
  • Avoid an unnecessary supply upgrade — or plan one with confidence if the data shows you need it.

Cut energy costs and improve power quality

  • Identify cost-saving opportunities from energy efficiency measures.
  • Improve a building’s power factor, which is inflating the bill.
  • Reduce peak-demand (KVA) charges — monitor what is causing high KVA usage and when.
  • Balance loads across phases to prevent overloading one phase.

Size solar, storage and backup systems

  • Plan solar PV systems and determine the number of panels needed.
  • Plan backup power systems — determine inverter and battery capacity.
  • Determine backup generator size requirements.

What’s In The Box?

  • Meatrol ME537 Energy Logger

Rogowski Coils or CTs(Current Transformers)?

The Meatrol ME537 works with Rogowski coils or CTs (Current Transformers). These are not supplied with the meter; you need to purchase them separately in the sizes you require. Click the links below to add them to your order.

Specifications

Description
TypeThree-phase power quality analyser, 96 × 96 mm panel mount
ModelME537 (ME537C: variant with 5 A inputs for existing X/5 A CTs)
ApplicationPower analysis, power measurement, power quality analysis
Wiring systems3P4W 4CT, 3P4W 3CT, 3P3W 3CT, 3P3W 2CT, 1P3W, 1P2W
Current sensorsRogowski coils or voltage-output current clamps/CTs (not supplied)
Voltage connectionDirect, or via voltage transformer
Display3.5-inch IPS colour display, 480 × 800
Dimensions96 × 96 × 94 mm
Weight850 g
Warranty2 years
Voltage
Input and measurement range0–600 V AC
Accuracy0.2 %
Current
Input range0–420 mV AC
Measurement rangeDepends on the current sensor
Accuracy0.2 % + accuracy of the current sensor
Frequency, power and energy
Frequency45–65 Hz, ±0.001 Hz
Power factor−1 to +1, ±0.005
Active and apparent power0.5 %
Reactive power1 %
Active and apparent energy0.5 %
Reactive energy1 %
Measured parameters
VoltagePhase voltages L1–L3, N-to-earth voltage, line voltages, crest factor, peak
CurrentPhase currents L1–L3 and N, crest factor, K-factor
PowerActive, reactive and apparent power per phase and total; power factor and fundamental power factor
EnergyActive and reactive energy per phase and total (import/export), apparent energy, CO2 emissions
HarmonicsTHD, odd THD and even THD; individual harmonics 1st–50th (% and value), voltage and current
OtherWaveforms, phase angles, voltage and current unbalance, demand and peak demand, max/min values
Recording
Storage32 GB TF card, CSV format, export via USB flash drive
RecordsInterval data, voltage and current harmonic records, events (swells, dips, interruptions, frequency, unbalance, harmonics), waveform records
Inputs and outputs
Digital inputs2 dry-contact inputs
Relay outputs2 relays, each with normally open and normally closed contacts
Communication
EthernetRJ45, Modbus TCP
RS485Modbus RTU
Power supply
Auxiliary supply85–305 V AC / 100–430 V DC
Maximum consumption5 VA
Environment and safety
Operating conditions−20 °C to +55 °C, below 90 % RH
Storage conditions−40 °C to +70 °C, below 95 % RH (non-condensing)
Altitude≤ 2,000 m
Measurement categoryCAT III 600 V
Ingress protectionIP30

Frequently Asked Questions

This meter is not supplied with any Rogowski coils or CTs (Current Transformers). You need to purchase these separately in the sizes you require. Click the links below to add them to your order.

This meter has current input connections for three phases plus neutral, so it requires four coils or CTs in total.

The meter is not powered up by the voltage from the voltage sensing input ports. Separate power needs to be wired to the power supply ports of the meter. The meter can be powered by AC power from 85V to 305V.

Meatrol ME537 power connection

This meter is not supplied with any Rogowski coils or CTs (Current Transformers). You need to purchase these separately in the sizes you require. Click the links below to add them to your order.

The sample rate can be set to one of the following values:
0= 1kHz
1= 2kHz
2= 4kHz
3= 8kHz

The minimum logging interval of the ME537 is five seconds. Because of the amount of data recorded, shorter logging intervals are not possible.

Yes. The ME537 measures 0–600 V AC and is rated CAT III 600 V, so a 525 V three-phase system (about 303 V line-to-neutral) is within its range for direct connection.

This makes the ME537 a good fit for South African mining and heavy-industry panels, where 525 V is common.

No. Voltage transformers are not needed on 525 V systems. Wire the voltage inputs directly to the phases, protected by suitable fuses as you would for any panel meter.

Yes. If the voltage inputs are left unconnected, the ME537 still measures and displays current correctly on all three phases. This suits applications such as motor starter panels, where only the current reading is needed.

Two points to bear in mind:

  • The meter still needs its auxiliary supply wired to the power terminals.
  • Power, energy and power-factor values need the voltage inputs. Without them, only the current readings are meaningful.

Yes. Leave the current inputs unconnected and all voltage-related functions work normally, including voltage and frequency measurement and the recording of voltage events such as dips, swells and interruptions.

Two points to bear in mind:

  • The meter still needs its auxiliary supply wired to the power terminals.
  • Power, energy and power-factor values need current sensors. In a voltage-only installation, ignore these readings.

The ME537 detects voltage events in line with EN 61000-4-30. The manufacturer confirms that it captures events as short as 10 ms – half a cycle at 50 Hz. This covers the short dips and interruptions of 10–100 ms that typically upset sensitive production equipment.

To capture short events, enable both the data recorder and the waveform recorder. Waveform recording supports sample rates of up to 8 kHz.

Each event record contains the event type (for example dip, swell or interruption), the timestamp, the duration and the amplitude. Records are saved as CSV files on the meter’s 32 GB storage and exported via USB flash drive.

Partly. The live alarm status can be read remotely over Ethernet (Modbus TCP), so a SCADA or monitoring system can see when an alarm is active.

The complete historical event log cannot be retrieved over Modbus TCP. It is exported locally to a USB flash drive. If your application needs fully remote access to the recorded event history, contact us before ordering and we will advise on the best set-up.

The minimum update interval for live voltage and frequency over Modbus TCP is 200 ms. This suits live dashboards and SCADA trending, but polling at this rate cannot reliably catch dips of 10–100 ms. For short events, rely on the meter’s built-in event and waveform recorder, which detects them on board.

This is separate from interval data logging, where the shortest logging interval is five seconds.

Yes. Use NRC-100 Rogowski coils (sensitivity 50 mV/kA) and set the meter to the 6,000 A range. At 6,000 A the coil delivers about 300 mV, well within the 500 mV input limit.

Under Setup → Network → Current Sensor, enter:

  • Type: Rogowski
  • Sensitivity: 50 mV/kA
  • Range: 6000 A
  • Ratio: 0001.0000

The NRC-100 has a 100 mm window, so it fits comfortably around large busbars such as 60 × 10 mm copper.

Yes. The ME537 stores the maximum current value for each phase. This lets you see the peak starting current of a direct-on-line (DOL) motor after each start.

The maximum values can be reset after commissioning, either on the meter display or via communication. That way, test runs during commissioning do not distort the values recorded in normal operation.

Frequently Asked Questions – Current sensors

The ME537 has voltage-signal current inputs (maximum 500 mV). It works with two sensor types:

  • Rogowski coils – signal given in mV/kA at 50 Hz
  • 333 mV output current transformers (CTs) – signal given in mV/A

Both types are selected under Setup → Network → Current Sensor, where you set the Type, Sensitivity, Range and Ratio for the three phases (ABC) and the neutral (N) independently.

The meter is supplied without sensors. You need four in total – three phases plus neutral.

Every iron-cored current transformer produces a current in its secondary winding. The difference is simply whether a burden resistor is fitted inside the sensor or not.

Current-output CT – the traditional switchgear type, rated X/5 A or X/1 A. It has no internal burden. It behaves as a current source and delivers its rated secondary current into whatever is connected to it, with the burden provided externally by the connected meter or relay. If the secondary is left open while the primary is energised, the CT generates a dangerously high voltage. These are the CTs that carry the familiar “never open-circuit a live CT” warning.

Voltage-output CT (333 mV) – physically the same iron-cored transformer, but with a precision burden resistor permanently fitted inside the housing. You measure the voltage across that resistor, so the output is a low-level signal in millivolts. It is safe to open-circuit, safe to handle, and can be run on ordinary thin signal cable. 333 mV at nominal current is the widely used standard, and it is what the ME537 expects.

A Rogowski coil is not a transformer with a resistor added. It has no iron core at all – it is a helical winding on a flexible former, closed into a loop around the conductor.

  • It cannot saturate. Accuracy holds across very high currents and heavy distortion.
  • Very wide measuring range. A single coil covers a large span of load currents.
  • Flexible and easy to fit. It opens and closes around busbars, cable bundles and awkward terminations without disconnecting anything.
  • Light and compact, even for large primary currents.
  • AC only. A Rogowski coil cannot measure DC.

Its output is specified in mV/kA at 50 Hz, which is why the ME537 uses a different sensitivity unit for this type.

Not with the standard ME537. Its current inputs are voltage inputs, with an input range of 0–420 mV AC, and they require either a Rogowski coil or a 333 mV output CT. A conventional X/5A CT is a current source and must not be connected to them — doing so damages the meter input and causes the CT to generate a hazardous voltage at its terminals.

For installations with existing X/5A metering CTs, order the ME537C instead. This variant has 5A current inputs designed to connect directly to standard panel CT secondaries. All other functions and settings are identical to the standard ME537.

On the ME537C, you only need to set the Ratio under Setup → Network → Current Sensor to match your CT ratio:

  • 600/5A CT → Ratio 0120.0000
  • 800/5A CT → Ratio 0160.0000

The meter then displays and logs the true primary current.

If you are unsure which version suits your installation, contact us with your CT details before ordering.

Rogowski coil — flexible, opens and closes around the conductor. Best for large or awkward conductors, busbars, cable bundles, tight enclosures, very high currents, and distorted or non-linear loads. Cannot saturate, and one coil covers a wide range of load currents. AC only.

333mV split-core CT — rigid, iron-cored, clamps around a single cable. Best for fixed small-to-medium feeders and permanent installations where the cable is accessible and the load current is well within the CT’s rating.

As a rule: if the conductors are easy to reach and the current is modest, a 333mV CT is the simpler and more economical choice. If access is difficult, the conductors are large, or the current is high or heavily distorted, choose a Rogowski coil.

Whichever type you select, you need four sensors in total — three phases plus neutral — and they must match the current range you intend to measure.

The values are printed on the sensor and entered under Setup → Network → Current Sensor.

  • Rogowski coil: Type Rcoil, Sensitivity in mV/kA @ 50 Hz (for example 50.00), Range set to the coil’s nominal primary current.
  • 333 mV CT: Type CT, Sensitivity in mV/A, Range set to the CT’s primary rating. A 333 mV CT’s sensitivity is 333 divided by its primary rating – 3.33 mV/A for a 100 A CT, 0.555 mV/A for a 600 A CT.
  • Ratio: leave at 0001.0000 when the sensor is fitted directly over the measured conductor. Change it only where the sensor is fitted over the secondary of another CT.

Phases and neutral are configured separately, so a Rogowski coil on the phases and a CT on the neutral – or any other combination – is perfectly valid.

Yes. The ABC phases and the N channel each have their own Type, Sensitivity, Range and Ratio settings. Mixed installations are common where the neutral is more accessible than the phases, or where a different current range applies to the neutral.

Meter data analysis, visualisation and reporting

We have created an Excel template that can analyse the data and visualise it with graphs. It has the following features and graphs.

  • Maximum power per minute, hour and day
  • Energy usage per minute, hour and day
  • Maximum voltage per minute, hour and day
  • Limit data displayed to a specific day or hour
  • Supports three-phase and single-phase setups

This template and support with importing the data and using the template are included free of charge when purchasing this meter.

The template is very easy to use even for users that is not that familiar with Excel. We have also created step by step instructions document and video.

Click here to find out more.

Warranty

All measurement instruments sold by AmpX are covered by the manufacturer’s warranty (typically 24 months on the main instrument, 12 months on accessories such as test leads, clamps and batteries). Exact terms are stated on the warranty card supplied with the device.

What you get at AmpX:

  • Warranty handled locally in Germany and South Africa — no overseas returns required
  • 30-day no-questions-asked return policy
  • Local spare parts and repair service for selected brands, like Meatrol.
  • Direct technical contact by phone, email or WhatsApp for any warranty issue

Warranty issue? Please contact us:
E-Mail: info at ampx dot co
WhatsApp: +27 61 127 0782
Call: +27 61 127 0782

AmpX Management

warranty 2 years

Technical support

If you have any difficulty with the meter setup, installation, data analysis, or anything else, we will gladly support you.

Please contact our technical support department for technical support
E-Mail: info at ampx dot co
WhatsApp: +27 61 127 0782
Call: +27 61 127 0782

AmpX Technical Support

Free Demonstration

We can offer you a free demonstration of our energy meters at our premises or within 100 km. If further away, we will need to charge for our travel expenses.

Alternatively we can also do an online video consultation and demonstration.

Click here to request a demonstration if 100 km from our address.

Click here to schedule an online video call and demonstration.

AmpX Demonstration

Key Takeaways

  • The Meatrol ME537 Energy Logger requires separate purchase of Rogowski coils or CTs (Current Transformers).
  • The ME537 features a 3.5-inch colour display and measures current, voltage, power, energy and harmonics up to the 50th order.
  • It communicates over Ethernet (Modbus TCP) and RS485 (Modbus RTU).
  • It records data, events and waveforms to an internal 32 GB memory card.
  • This page provides downloads for manuals, firmware, and certificates for efficient usage.

You may also like…

  • R 690.00 Incl. VAT
  • Split Core Current Transformer
    R 200.00 Incl. VAT
  • Flexible rogowski coil – NRC series – 100mm to 300mm diameter
    Price range: R 890.00 through R 1 348.00 Incl. VAT

Join our Newsletter

Stay up to date with the latest product developments and get 5% off your first order.

This field is for validation purposes and should be left unchanged.
Name(Required)
Privacy(Required)

FAST, RELIABLE DELIVERY

We deliver nationwide using courier services.

SAFE AND SECURE PAYMENT

We accept multiple payment methods, EFT, Credit Card, or TradeSafe.

EXPERT ADVICE AND SUPPORT

We are available to help via live chat, email, phone, and video calls.