225+ Electricians, Engineers and Energy professionals
trust and use our products.
PVM-1020 Solar Test Kit
R 44 700.00
Great capabilities in a small casing
1. PVM-1020 photovoltaic meter The Sonel PVM-1020 meter is probably the world’s smallest photovoltaic system meter with a substantial number of measurement functions. The functions are selected with a rotary switch. Additional parameters are set with buttons located on the housing. All buttons and the graphic display are backlit, which greatly facilitates operation in shaded places, e.g. when taking measurements under ground-mounted PV systems. Large memory significantly shortens the preparation of documents after the measurement.
2. IRM-1 solar radiation and temperature meter IRM-1, small, but indispensable for testing PV systems. By measuring solar radiation values, as well as panel and ambient temperatures, it provides the necessary data to convert the results into STC conditions. A built-in recorder with a memory of 5000 records enables the instrument to be used as a tool in the PV plant design process, as well as to diagnose panel shading problems.
Would you like to be notified when this item is back in stock? Then please fill in the following form:
Overview:
Features:
- It can be used for category 1 measurements according to IEC 62446-1.
- AUTO mode for performing a sequence of measurements after one press of the START button.
- It converts measured parameters into STC conditions according to IEC 60891 by cooperation with the IRM-1 solar radiation and temperature meter.
- reSYNC function – automatic completion of results with environmental parameters and their conversion to STC conditions after restoring connection with IRM-1.
- The built-in LoRa radio interface ensures cooperation with the IRM-1 meter over long distances.
- Built-in Bluetooth module for communication with a computer.
- Large measurement memory: 100 objects with 40 cells each.
- Backlit display and buttons.
Measured parameters:
- The open circuit voltage of the PV panel or a chain of panels, up to 1000V DC.
- RMS voltage of the AC network up to 600 V with frequency measurement.
- Short circuit current of a PV panel or chain of panels – up to 20 A DC.
- Insulation resistance of PV panels – measuring voltage of 250, 500 or 1000 V, simultaneous measurement of two values: RISO+ and RISO-.
- Insulation resistance of AC circuits – measuring voltage 250, 500 or 1000 V.
- Resistance of protective conductors and equipotential bonding with ± 200 mA current. Low-current resistance measurement, audible and visual signaling.
- Measurement of PV panels operating current and AC current – all with external clamp.
- AC/DC power Measurement.
- Diode test with 200 mA current, automatic polarity detection. Test of blocking diodes with 1000V DC voltage.
Tightness and durability:
The meter performs well in harsh environmental conditions. Protection against the ingress of dust and water is provided by the housing rated at IP65. This is especially important for measurements on photovoltaic systems, which are outdoor installations.
Communication and software:
Measurement data from the PVM-1020 can be transferred to a computer via Bluetooth wireless communication. Saving the downloaded data to popular formats.
Specifications:
Parameter | Measurement range | Display range | Resolution | Accuracy |
Voltage | ||||
AC voltage | 0.0 V…600.0 V | 0.0 V…600.0 V | 0.1 V | ±(2% m.v. + 2 digits) |
DC voltage | 0.0 V…1000.0 V | 0.0 V…1000.0 V | 0.1 V | ±(0.5% m.v. + 2 digits) |
Short circuit current ISC | 0.0…20.0 A | 0.0…20.0 A | 0.1 A | ±(1% m.v. + 2 digits) |
Insulation resistance | ||||
Insulation resistance at AC side | ||||
Measuring voltage 250 V | 250 kΩ…2.000 GΩ acc. to IEC 61557-2 | 0.0 kΩ…2.000 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
Measuring voltage 500 V | 250 kΩ…5.000 GΩ acc. to IEC 61557-2 | 0.0 kΩ…5.000 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
Measuring voltage 1000 V | 500 kΩ…9.999 GΩ acc. to IEC 61557-2 | 0.0 kΩ…9.999 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
Insulation resistance at DC side | ||||
Measuring voltage 250 V / 500 V / 1000 V | 250 kΩ…1.000 GΩ acc. to IEC 61557-2 | 0.0 kΩ…1.000 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
Resistance of protective conductors and equipotential bondings | ||||
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current | 0.10 Ω…1999 Ω acc. to IEC 61557-4 | 0.00 Ω…1999 Ω | from 0.01 Ω | ±(2% m.v. + 3 digits) |
Measurement of resistance with low current | 0.0 Ω…1999 Ω | 0.0 Ω…1999 Ω | from 0.01 Ω | ±(3% m.v. + 3 digits) |
Current measurement | 0.0 A…400.0 A | 0.0 A…400.0 A | from 0.01 Ω | ±(5% m.v. + 2 digits) |
Power measurement | 0.0 kW…100.0 kW | 0.0 kW…100.0 kW | 0.1 kW | ±(6% m.v. + 5 digits) |
Features:
- Measurement of solar radiation and temperature.
- The LoRa interface for communication with a master meter – offers a larger range than the Bluetooth technology!
- Automatic data synchronisation with a master meter with reSYNC function.
- Built-in compass and inclination sensor.
- Built-in recorder that can be used to record solar radiation before constructing PV systems, as well as to measure the shading of existing systems.
- Large measurement memory: 999 cache memory cells and 5000 recorder, records available (one-time recording) with the option of overwriting them (continuous recording).
Measured parameters:
- Solar radiation intensity (irradiance) in W/m2 or BTU/ft2 h.
- PV panel temperature in °C or °F.
- Ambient temperature in °C or °F.
- Inclination angle of panels
- Orientation of the panels with the built-in compass.
Protection and durability:
The meter performs well in harsh environmental conditions. Protection against the ingress of dust and water is provided by the housing rated at IP65. This is especially important for measurements on photovoltaic systems, which are outdoor installations.
Communication and software:
Measurement data from the IRM-1 can be transferred to a computer via the USB port. In addition, the device has a built-in wireless LoRa interface (Long Range) for automatic data exchange with the master meter – even over long distances.
Specifications:
Parameter | Measurement range | Display range | Resolution | Accuracy |
Irradiance | ||||
Measurement in W/m² | 100 W/m² …1400 W/m² | 0 W/m² …1400 W/m² | 1 W/m² | ±(5% m.v. + 2 digits) |
Measurement in BTU/ft² h | 32 BTU/ft² h…444 BTU/ft²h | 0 BTU/ft² h…444 BTU/ft² h | 1 BTU/ft² h | ±(5% m.v. + 2 digits) |
PV and ambient temperature | ||||
Measurement in °C | -20.0°C…100.0°C | -20.0°C…100.0°C | 0.1°C | ±(1% m.v. + 5 digits) |
Measurement in °F | -4.0°F…212.0°F | 4.0°F…212.0°F | 0.1°F | ±(1% m.v. + 5 digits) |
Inclination angle | -90°…+90° | -90°…+90° | 1° | ±2° |
Position direction – compass | 0°…360° | 0°…360° | 1° | ±5° |